Rate this post

Free Sales Ending Soon – Use Real M2 PDF Questions [Sep 22, 2026]

Updated Sep-2026 Exam M2 Dumps – Pass Your Certification Exam

International Code Council M2 Exam Syllabus Topics:

Section Weight Objectives
Topic 1: Chimneys & Vents 14% – Factory-built chimneys and vents
– Clearances and termination requirements
– Chimney construction and materials
– Vent systems and connections
Topic 2: Heating, Cooling & Water Heaters 18% – Water heaters and storage tanks
– Heat pumps and cooling equipment
– Solar thermal systems
– HVAC equipment installation and clearance
– Boilers and hydronic systems
Topic 3: General Administration 18% – Plan review and documentation
– Manufacturer’s instructions and listings
– Permits and inspections
– Code authority and enforcement
Topic 4: Combustion Air 8% – Air supply and venting
– Combustion air requirements
– Confined spaces and equipment rooms
Topic 5: Exhaust & Ventilation Systems 20% – Commercial kitchen exhaust systems
– Makeup air systems
– Ventilation rates and outdoor air requirements
– Hazardous and special exhaust systems
Topic 6: Fuel Supply Systems 10% – Gas appliances and connections
– Fuel gas piping materials and installation
– Piping testing and inspection
– Pressure regulation and overpressure protection
Topic 7: Duct Systems 12% – Duct construction and materials
– Insulation and sealing
– Dampers and access doors
– Duct installation and supports

 

Q21. Given: The listed clearance is 12 inches.

What would be the reduced clearance to combustibles, in inches, if the millboard is replaced with 24-gauge sheet metal?

 
 
 
 

Q22. What is the minimum distance required between a combustion air opening at the exterior of a building and a lot line?

 
 
 
 

Q23. Exhaust is required for which of the following areas?

 
 
 
 

Q24. Given: An industrial water heater boiler has a manufacturer’s listing of 18 inches wall clearance. It is installed with a protective wall assembly of 24-gauge sheet metal spaced out 1 inch from the wall.
The reduced installation clearance from the wall for this appliance is _____ inches.

 
 
 
 

Q25. Exposed solar thermal equipment protected by motor vehicle impact may be installed at what height?

 
 
 
 

Q26. Supports for hazardous exhaust duct shall be constructed of:

 
 
 
 

Q27. Exhibit:

CEF-5 is a ceiling exhaust fan manufactured by:

 
 
 
 

Q28. An equipment shutoff valve shall be in the same room and not more than how many feet away from the appliance?

 
 
 
 

Q29. A cooling system with a condensate disposal system:

 
 
 
 

Q30. The minimum size for access openings for fire dampers shall be:

 
 
 
 

Q31. The exhibit shows a _____ in. diameter gas line between unit heaters 5 and 8.

 
 
 
 

Q32. When a furnace is installed in a 66-inch-high attic, the maximum distance from the passageway access to the furnace shall be _____ ft., measured along the centerline of the passageway.

 
 
 
 

Q33. Air mechanically exhausted from a room must be:

 
 
 
 

Q34. When testing dampers located in corridors, the dampers shall demonstrate acceptable closure performance when subjected to _____ fpm velocity across the face of the damper using the UL 555 fire exposure test.

 
 
 
 

Q35. Horizontal terminations for mechanical draft systems that are adjacent to public walkways shall be located a minimum of _____ feet above grade.

 
 
 
 

Q36. What is the minimum air velocity that must be provided by an exhaust duct system serving a Type I range hood?

 
 
 
 

Q37. What is the maximum distance allowed below the design flood elevation from which ventilation may be obtained?

 
 
 
 

Q38. A low-pressure steam heating boiler is a boiler furnishing a maximum steam pressure of _____ psi.

 
 
 
 

Q39. The optional integral clearance reduction system is designed to meet which NFPA standard?

 
 
 
 

Q40. Exhibit:

What hp is EF-2?

 
 
 
 

Q41. For the installation of listed fuel-burning appliances, the required clearances should be found:

 
 
 
 

M2 Dumps To Pass Commercial Inspector Exam in One Day: https://www.pdf4test.com/M2-dump-torrent.html

Related Links: www.fotor.com www.stes.tyc.edu.tw myportal.utt.edu.tt www.stes.tyc.edu.tw www.stes.tyc.edu.tw www.stes.tyc.edu.tw